Inspection Protocols

Summary

When you request an inspection from Modern Insurer, you are required to provide a protocol property in the API request.

POST /api/inspections

{  
  "propertyId": "6753cc4c53615a110e62b051",
  "type": "claim",
  "protocol": "wildfire", // required, defines inspection scope
  "claimId": "674c7271b44d3674bd14f9c0",
  "note": "roof damaged during Caldor fire. roof rebuild must satisfy IBHS wildfire prepared criteria."
}

Protocols define scope and ensure the outcome of the inspection meets expectations. Each protocol has a fixed cost and are listed with each line item in an invoice.

Supported Protocols

ProtocolCodeTechnical Standard
IBHS Wildfire Prepared HomewildfireLink

📘

Need Something Else?

The Modern Insurer architecture is easily extendable to support additional protocols. We are always adding additional protocols to ensure a comprehensive set of inspection needs are met. Reach out and we can work with you to add additional protocols.

Protocol Requirements

Wildfire

RequirementDescription
Non-Combustible ZoneThe area within 0-5 feet of the home and attached structures shall be free of all combustible materials, vegetation, and objects.
Ground Cover Near StructureGround cover in the 0-5 foot zone shall consist of non-combustible materials such as rock, gravel, concrete, or maintained lawn.
Grass and Weeds HeightGrass and weeds shall be maintained at a maximum height of 4 inches.
Leaf Litter and Debris RemovalLeaf litter, bark, twigs, and other debris shall not be present.
Tree Branch DistanceTree branch ends shall be at least 5 feet away from structures.
Firewood StorageFirewood, lumber, and other combustible materials shall not be present.
Roof RatingRoof coverings shall be rated Class A and in good condition with no missing or damaged pieces.
Roof DebrisRoofs, gutters, and downspouts shall be free of accumulated debris.
Skylight MaintenanceSkylights shall not have accumulated debris on or next to them.
Vent MeshAll vents shall be covered with 1/8-inch to 1/16-inch metal mesh.
Chimney ProtectionChimney and stovepipe outlets shall be covered with spark arrestors meeting NFPA 211 standards.
Siding IntegritySiding and trim shall be in good condition with no damage, gaps, or holes.
Foundation Vent ProtectionFoundation and crawl space vents shall be covered with 1/8-inch to 1/16-inch metal mesh.
Eave ConstructionOpen eave framing and exposed rafter tails shall not be present.
Window ConstructionWindows shall be multi-paned with at least one pane being tempered glass.
Garage Door GapsGarage doors shall be free of gaps greater than 1/8-inch at edges and base.
Deck ConditionDecking boards shall be in good condition with no damage, warping, or gaps.
Under-Deck MaintenanceAreas under decks shall be free of combustible materials and debris.
Deck ConnectionDeck attachments to the home shall be in good condition and properly flashed.
Address MarkingAddress numbers shall be clearly visible from the street with numbers at least 4 inches high.
Driveway ClearanceDriveways shall maintain at least 13.5 feet of vertical clearance and 10 feet of horizontal clearance.
Tree Canopy SpacingTree canopies shall be spaced at least 10 feet apart.
Extended Zone Ground CoverGround cover shall be maintained to a maximum height of 4 inches.
Tree Height ManagementTrees taller than 18 feet shall be limbed up 6 feet from the ground.
Extended Zone VegetationNo dead vegetation shall be present within 30 feet of structures.
Enhanced Eave ProtectionAll eaves shall be enclosed with no exposed rafter tails.
Enhanced Vent ProtectionAll vents shall have ember-resistant features or baffles.
Gutter ProtectionGutters shall have non-combustible gutter guards installed.
Enhanced Deck MaterialsDecking shall be constructed of non-combustible or fire-resistant materials.
Water AvailabilityProperty shall have a reliable water supply for fire fighting.
Secondary AccessSecondary emergency vehicle access route shall be available where possible.